D
THE ADT-UZC-256
UNIVERSAL ZONE CODER
for the Unimode
®
2020/1010, Unimode
®
II and Unimode
®
4-16
Fire Alarm Control Panels
Document 51349
4/25/00 Rev:
A15216:D ECN 99-402
One Town Center Road
Boca Raton, FL 33431
Phone: (561) 988-3600
FAX: (561) 988-3675
Security Services Inc.
Vue de la page 0
1 2 3 4 5 6 ... 14 15

Résumé du contenu

Page 1 - UNIVERSAL ZONE CODER

DTHE ADT-UZC-256UNIVERSAL ZONE CODERfor the Unimode® 2020/1010, Unimode® II and Unimode® 4-16Fire Alarm Control PanelsDocument 513494/25/00 Re

Page 2 - Fire Alarm System Limitations

1051349:D 4/25/00Unimode 2020/1010 InstallationMechanical InstallationIn a Unimode 2020/1010, the ADT-UZC-256 plugs into a slot on the ICA-4L chassis

Page 3 - Installation Precautions

1151349:D 4/25/00Section Four:Power/NAC ConfigurationsThese two NotificationAppliance Circuits share3.0 amps of coded power.NOTE: Cable from MPS to A

Page 4 - Contents

1251349:D 4/25/00These two NotificationAppliance Circuits share3.0 amps of coded power.These two NotificationAppliance Circuits share3.0 amps of code

Page 5 - Section One:

1351349:D 4/25/00Section Five:Unimode 2020/1010 / ADT-UZC-256 ConfigurationMPS-24ABell PowerBATTERY BATTERY3 AMP MAX.Universal ZoneCoderADT-UZC-256XP

Page 6 - Standby Battery Calculation

1451349:D 4/25/00Section Six:ADT-UZC-256 Connections to M300CADT ModulesSystem Sensor A2143-00(Canada: N-ELR)End-of-Line Resistor, 47K, .5 watts,supe

Page 7 - Board Description

1551349:D 4/25/00Appendix A:Plug/Terminal SchematicCode Relay 3Code Relay 2Code Relay 1Coded Outputs32 1Coded Output 3Power Input 3Coded Output 2Powe

Page 8 - Electrical Installation

Precau-Lg.p65 01/18/2000An automatic fire alarm system–typically made up of smokedetectors, heat detectors, manual pull stations, audible warn-ing

Page 9

Precau-Lg.p65 01/18/2000WARNING - Several different sources of power can be con-nected to the fire alarm control panel. Disconnect all sourcesof p

Page 10 - Mechanical Installation

451349:D 4/25/00ContentsSection One:ADT-UZC-256 Universal Zone Coder ... 5Section Two:Board Des

Page 11 - Power/NAC Configurations

551349:D 4/25/00Section One:ADT-UZC-256 Universal Zone CoderGeneralThe ADT-UZC-256 Universal Zone Coder provides separate codes for up to 256 initiat

Page 12 - 51349:D

651349:D 4/25/00MountingThe ADT-UZC-256 plugs into the ICA-4L in Unimode 2020/1010 systems, or mounts behindmodules in the Unimode 4-16 and Unimode I

Page 13 - UZC-2020.CDR

751349:D 4/25/00TROUBLE LED (Yellow)Lights when one or more trouble conditions are detected.ALARM TEST (Red)Follows the main coded output.SLC ON-LINE

Page 14 - ADT-UZC-256

851349:D 4/25/00Figure 3-1: Mounting the ADT-UZC-256 to a CHS-4Section Three:Installing the ADT-UZC-256Unimode II InstallationMechanical Installation

Page 15 - Plug/Terminal Schematic

951349:D 4/25/00Unimode 4-16 InstallationMechanical InstallationIn a Unimode 4-16, the ADT-UZC-256 mounts beneath the third (right most) module. TheA